ACLD-9182A/B
16-CH Opto-Isolated Digital Input Termination Board
Isolation and Dry Contact / Non Polarized Opto Isolated !!



Description

The ACLD-9182A/B opto-isolated D/I termination board provides 16 optically isolated digital inputs for use with any ACL series I/O board with D/I channels on 20-pin flat ribbon connectors.

Optical isolation provides a good solution in the prevention of floating potential and ground loop problems.

Each input channel has a red LED to reflect the input status. If the input voltage is high, the LED will light, otherwise the LED is off. Each input channel is jumper selectable to be either AC-filter or non-AC-filter.

Non-Polarized, Opto-Isolated Digital Input (ACLD-9128B only). The digital input is first routed through a photocoupler (PC-814), so that the connections are not polarity sensitive whether used on AC or DC voltage. Also, a single-pole filter with a time constant about 5ms is used to filter when the AC inputs pass through. The outstanding features of this circuitry are:
- Non polarity sensitive digital input
- Both DC or AC (50~1000 Hz) inputs
- Up to 1,000 V isolation coltage
- DC noise rejection (spikes or constant debouncing)

  Retour

Features

  • 16 opto-isolated digital input channels
  • For use with ACL DAS Card 20-pin digital input connector
  • AC or DC polarity free digital input
  • On-board LEDs reflect the input logic status
  • Built-in screw terminals for easy input wiring
  • LEDs indicate status of relays

  Retour


Specifications

  • Input Range : 0~24 VDC
  • Opto-isolator : PC-814
  • Input channel : 16
  • Input signal : 3~24 VDC or AC , 50~1,000 Hz
  • Input impedance : 1.2 Kohm
  • Isolation voltage : 1,000 VDC channel-to-channel and channel-to-ground
  • Response time: 20 ”sec without AC filter, 2.2 msec with AC filter
  • Connector : 20-pin flat ribbon cable connector
  • Screw terminal: #22 to #12 AWG wires

    ACLD-9128A ACLD-9128A
    Input range 0 ~ 24 VDC 0 ~ 24 VDC
    Input signal Threshold Voltage
    1.5 V
    DC adjustable
    3 ~ 24 VDC or
    AC (50 ~ 1,000 Hz)
    Opto isolator 4N 35 PC-814
    Input voltage DC only AC / DC
    Input mode Isolation and dry contact Isolation

 

Physical, Environmental

  • Dimensions : 205 mm x 114.3 mm
  • Operating temperature: 0 ~ 60șC
  • Storage temperature : -20 ~ 80șC
  • Humidity: 5~95%, non-condensing

  Retour


Ordering Information

ACLD-9182A : 16 CH Isolation / Non Isolation D/I Termination Board

ACLD-9182B : 16 CH Isolation AC/DC Termination Board

Retour